Welcome to Shumotek

Dec 15, 2016

METIS


Time-of-Flight Momentum Microscope

 

Category: News-EN
Posted by: administrator

Features:

  • Direct imaging of Energy Filtered 2D-Momentum Space
  • Parallel Detection of up to 400 Energy Slices
  • Energy Resolution < 15 mev
  • Angular/k Resolution 0.1° / < 0.01 Å-1
  • Start Energies 0-1500 eV
 
Product Description:

The METIS spectrometer is a joint development of the Johannes-Gutenberg Universität Mainz and the MPI für Mikrostrukturphysik Halle. It is produced by Surface Concept and integrated by SPECS into complete and versatile UHV systems. It consists of a sample stage, a sophisticated lens system and an analyzer section. The sample stage is a high precision 6-axes hexapod for optimal alignment of the sample towards the lens entrance. The k-microscopy column comprises multiple lens system with a high extractor voltage to analyze the full half space of photoelectrons. The analyzer section is a drift tube with a 2D-DLD detector, which can be upgraded by a spin-imaging detector.

k-Microscope Column The core of the METIS spectrometer is the lens system. With its high extractor voltages it records photoelectrons with a start energy up to 70 eV
over the full half space, simultaneously in kx and ky direction. This is a big advantage compared to conventional hemispherical analyzers, where only a small fraction can be measured at once. The result is a 3D dataset of Ekin, kx and ky, combined with a time resolution of 150 ps from the delay line detector and maximum count rates of 8 Mcps. The lens system allows for energy dispersive measurements as well as real space images. Additional apertures inside the lens system can reduce the field of view for
ARPES spectra of small areas down to μm regions or enhance the contrast for photoelectron microscopy with chemical information.

The kinetic energies of the electrons are detected in time-of-flight mode using a delayline detector (DLD). A DLD is a position (x, y) and time (t) sensitive microchannel plate area detector for imaging of single particles with temporal resolution in the picosecond range. The (x, y, t) histograms are gathered over a large number of excitation cycles of the particle generating process as the system is a single counting device. Particle images can be collected from continuous running processes with randomly incoming particle sequences without time correlation as well. The dead times of these single counting devices are typically between 6 - 20 ns, depending on the positions of subsequent hits. That enables live imaging with highest sensitivity, collecting high count rates of randomly incoming particles in the multimillion counts per second range, as well as imaging with a very high dynamic range of 106. Unlike other pico-second imaging devices, delayline detectors collect all incoming particle hits continuously without any gate window duty cycles, thus (besides the device dead time limits) all hits are collected even when they represent random time positions within the excitation cycle time period. Any gate window can be configured even after acquisition, thus flexible re-ordering of data is possible without repeating measurements.

http://www.specs.de/cms/upload/bilder/METIS/SPECS_METIS-Brochure.pdf

News

METIS

Time-of-Flight Momentum Microscope

 

Read more...

EnviroESCA

EnviroESCA™

Electron Spectroscopy for Chemical Analysis under...

Read more...

NexGeneration UHV Suitcases

VSN40S UHV Suitcase with Cryo options 

Product code:...

Read more...

Nanonis Tramea

 quantum transport measurements


...
Read more...